Your Newest Supplier in the Analytical Chemistry Market...

Adrona provides laboratory water solutions to any application - starting from Primary Grade Water (Grade 3) for simple washing and autoclave feed to Purified Water (Grade 2) for general laboratory use or Ultrapure Water (Grade 1) for highly sensitive applications.

The systems are manufactured based on more than two decades of experience in laboratory water purification, using verified configurations of systems and high grade components and materials.

The systems are installable by user and all cartridges and filters are user-replaceable. The initial set of consumables is delivered with each of our water system.

Adrona water purification systems can be installed either on a laboratory bench or on a wall. Wallmount installation provides savings of valuable laboratory space. Requirements of GLP are met by the new Gradus and Connect LT systems.

VOLUMETRIC DISPENSE

Adrona water purification systems feature a volumetric dispenser, which enables the user to set accurate dispensing volume for each dispense cycle. The dispense volume can be set either from the keyboard or by using “teaching” mode. In “teaching” mode user uses “Dispense On/OFF” button to do the first dispense cycle manually. Afterwards, the system will dispense exactly the same volume each time the user presses the dispense button again.

WATER QUALITY AND VALIDATION

Embedded recirculation loop ensures stable premium water quality and enables practical elimination of Total Organic Carbon (TOC). Performance of deionization and polishing modules is constantly monitored. Monitoring algorithm enables cutting running costs, as replacement of the modules is requested only when service life is close to the end. Stability of water quality is achieved by double Ion Exchange cartridge system. (Adrona systems incorporate 2 Ion Exchange cartridges (deionization and polishing) therefore excellent water quality is guaranteed even if one of them is waiting for replacement at the moment.

Purified water quality of all our water purification systems can be validated by an external conductometer with flow cell which can be ordered from Adrona or bought locally.

Conformity of the systems to their specifications is provided in case the systems are properly installed and maintained.

TOTAL ORGANIC CARBON (TOC) MONITOR

Organic contaminants may not have effect on conductivity of water, so conductivity sensors cannot be used for TOC monitoring. Therefore, a special TOC monitoring module is needed to measure TOC level.
Several models of Adrona water purification systems have the TOC monitor feature. TOC values are shown on display.

DISPLAYS

Provide clear water quality readout and information about the system status including current resistivity and remaining pre-filter service life.

 

LARGE TOUCHSCREEN

Simplified and detailed information in multiple languages. Alarms and alerts are visible on the main screen with a complete information on actions required. Monitoring the operation system.

 

COLOUR GRAPHIC LCD DISPLAY

The 16-bit colour display provides clear readout of water quality, system component status, performance of the polishing module. System component status is reflected on the display in an intuitive colour pattern (Green/Yellow/Red).

 

MONOCHROME HIGH RESOLUTION LCD DISPLAY

System flowchart shows all component status and water quality parameters at a glance. Image can vary depending on model and its configuration.

 

ELECTRODEIONIZATION MODULE

For laboratories with high water consumption Adrona offers Q-Front or RADIX systems with an integrated EDI module. It allows to significantly reduce the running costs of water purification system due to EDI module which does not require replacement.

 

SAFETY

Adrona water purification systems feature all necessary safety functions. They are tested by an independent and accredited company for compliance with the CE directives related to safety and electromagnetic compatibility.

 

WARRANTY AND AFTER-SALES SUPPORT

Adrona provides 2 year warranty and continuous support. High customer satisfaction is our top priority in every aspect of business. Adrona’s support has been greatly appreciated by dealers worldwide for its reliability and willingness to help. Continously having all spare parts in stock enables us to guarantee short reaction times and quickly resolve any technical issues. Our support team is always ready to assist and in urgent cases dispatch the necessary components. Required repairs or technical maintenance is carried out by appropriately trained local personal or Adrona’s service engineers. In addition to spare parts, we ensure the availability of all consumables for the lifetime of every water purification system installed.

 

CERTIFICATION

ADRONA management system and manufacturing site operates in accordance with ISO 9001:2015. We are certified for manufacture, sale, and service of laboratory equipment.

 

CONFIGURATIONS ACCORDING TO APPLICATIONS

Each Adrona model is available in various configurations according to the customer needs 

Water for laboratory needs

RO

Grade 2

Grade 1

Applications

RO

Pure

EDI

Trace

HPLC

Bio

General laboratory applications

Glassware rinsing

Laboratory washers

Autoclaves

Electrochemistry

 

Wet chemistry

 

Spectrophotometry

 

Buffer and media preparation

 

Reagent preparation

 

Inorganic analysis methods

Flame atomic absorption spectrophotometry

 

Graphite automizer atomic absorption spectrophotometry

 

 

 

Plasma mass-spectrometry (ICP-MS)

 

 

 

Plasma spectrophotometry (ICP-OES)

 

 

 

Ion chromatography

 

 

 

Organic analysis methodes

Liquid chromatography (HPLC/UHPLC)

 

 

 

 

Gas chromatography

 

 

 

 

Total organic carbon measurments

 

 

 

 

Molecular Biology

Flow cytometry

 

 

 

 

 

Cell and tissue culture

 

 

 

 

 

Molecular biology