Adrona provides laboratory water solutions to any application - starting
from Primary Grade Water (Grade 3) for simple washing and autoclave feed to
Purified Water (Grade 2) for general laboratory use or Ultrapure Water (Grade
1) for highly sensitive applications.
The systems are manufactured based on
more than two decades of experience in laboratory water purification, using
verified configurations of systems and high grade components and materials.
The systems are installable by user and
all cartridges and filters are user-replaceable. The initial set of consumables
is delivered with each of our water system.
Adrona water purification systems can
be installed either on a laboratory bench or on a wall. Wallmount installation
provides savings of valuable laboratory space. Requirements of GLP are met by
the new Gradus and Connect LT systems.
VOLUMETRIC DISPENSE
Adrona water purification systems
feature a volumetric dispenser, which enables the user to set accurate
dispensing volume for each dispense cycle. The dispense volume can be set
either from the keyboard or by using “teaching” mode. In “teaching” mode user
uses “Dispense On/OFF” button to do the first dispense cycle manually.
Afterwards, the system will dispense exactly the same volume each time the user
presses the dispense button again.
WATER QUALITY AND VALIDATION
Embedded recirculation loop ensures
stable premium water quality and enables practical elimination of Total Organic
Carbon (TOC). Performance of deionization and polishing modules is constantly
monitored. Monitoring algorithm enables cutting running costs, as replacement
of the modules is requested only when service life is close to the end.
Stability of water quality is achieved by double Ion Exchange cartridge system.
(Adrona systems incorporate 2 Ion Exchange cartridges (deionization and
polishing) therefore excellent water quality is guaranteed even if one of them
is waiting for replacement at the moment.
Purified water quality of all our water
purification systems can be validated by an external conductometer with flow
cell which can be ordered from Adrona or bought locally.
Conformity of the systems to their
specifications is provided in case the systems are properly installed and
maintained.
TOTAL ORGANIC CARBON (TOC) MONITOR
Organic contaminants may not have
effect on conductivity of water, so conductivity sensors cannot be used for TOC
monitoring. Therefore, a special TOC monitoring module is needed to measure TOC
level.
Several models of Adrona water purification systems have the TOC monitor
feature. TOC values are shown on display.
DISPLAYS
Provide clear water quality readout and
information about the system status including current resistivity and remaining
pre-filter service life.
LARGE TOUCHSCREEN
Simplified and detailed information in
multiple languages. Alarms and alerts are visible on the main screen with a
complete information on actions required. Monitoring the operation system.
COLOUR GRAPHIC LCD DISPLAY
The 16-bit colour display provides
clear readout of water quality, system component status, performance of the
polishing module. System component status is reflected on the display in an
intuitive colour pattern (Green/Yellow/Red).
MONOCHROME HIGH RESOLUTION LCD DISPLAY
System flowchart shows all component
status and water quality parameters at a glance. Image can vary depending on
model and its configuration.
ELECTRODEIONIZATION MODULE
For laboratories with high water
consumption Adrona offers Q-Front or RADIX systems with an integrated EDI
module. It allows to significantly reduce the running costs of water
purification system due to EDI module which does not require replacement.
SAFETY
Adrona water purification systems
feature all necessary safety functions. They are tested by an independent and
accredited company for compliance with the CE directives related to safety and
electromagnetic compatibility.
WARRANTY AND AFTER-SALES SUPPORT
Adrona provides 2 year warranty and
continuous support. High customer satisfaction is our top priority in every
aspect of business. Adrona’s support has been greatly appreciated by dealers
worldwide for its reliability and willingness to help. Continously having all
spare parts in stock enables us to guarantee short reaction times and quickly
resolve any technical issues. Our support team is always ready to assist and in
urgent cases dispatch the necessary components. Required repairs or technical
maintenance is carried out by appropriately trained local personal or Adrona’s
service engineers. In addition to spare parts, we ensure the availability of
all consumables for the lifetime of every water purification system installed.
CERTIFICATION
ADRONA management system and manufacturing site operates in accordance with ISO
9001:2015. We are certified for manufacture, sale, and service of laboratory
equipment.
CONFIGURATIONS ACCORDING TO
APPLICATIONS
Each Adrona model is available in various configurations according to
the customer needs
Water for
laboratory needs
|
RO
|
Grade 2
|
Grade 1
|
Applications
|
RO
|
Pure
|
EDI
|
Trace
|
HPLC
|
Bio
|
General laboratory
applications
|
Glassware
rinsing
|
•
|
•
|
•
|
•
|
•
|
•
|
Laboratory
washers
|
•
|
•
|
•
|
•
|
•
|
•
|
Autoclaves
|
•
|
•
|
•
|
•
|
•
|
•
|
Electrochemistry
|
|
•
|
•
|
•
|
•
|
•
|
Wet
chemistry
|
|
•
|
•
|
•
|
•
|
•
|
Spectrophotometry
|
|
•
|
•
|
•
|
•
|
•
|
Buffer and
media preparation
|
|
•
|
•
|
•
|
•
|
•
|
Reagent
preparation
|
|
•
|
•
|
•
|
•
|
•
|
Inorganic analysis
methods
|
Flame
atomic absorption spectrophotometry
|
|
•
|
•
|
•
|
•
|
•
|
Graphite
automizer atomic absorption spectrophotometry
|
|
|
|
•
|
•
|
•
|
Plasma
mass-spectrometry (ICP-MS)
|
|
|
|
•
|
•
|
•
|
Plasma
spectrophotometry (ICP-OES)
|
|
|
|
•
|
•
|
•
|
Ion
chromatography
|
|
|
|
•
|
•
|
•
|
Organic analysis
methodes
|
Liquid
chromatography (HPLC/UHPLC)
|
|
|
|
|
•
|
•
|
Gas
chromatography
|
|
|
|
|
•
|
•
|
Total
organic carbon measurments
|
|
|
|
|
•
|
•
|
Molecular Biology
|
Flow
cytometry
|
|
|
|
|
|
•
|
Cell and
tissue culture
|
|
|
|
|
|
•
|
Molecular